Product Datasheet Search Results:

5SU1642-7KC63.pdf54 Pages, 2662 KB, Original
5SU1644-0KK82.pdf54 Pages, 2662 KB, Original
5SU1644-0KK82
Siemens
RCBO elm, instantaneous
5SU1644-1KK82.pdf54 Pages, 2662 KB, Original
5SU1644-1KK82
Siemens
RCBO elm, instantaneous
5SU1644-1RC32.pdf54 Pages, 2662 KB, Original
5SU1644-1RC32
Siemens
RCBO C32A,4P8M,300MA,AC
5SU1644-1RC40.pdf54 Pages, 2662 KB, Original
5SU1644-1RC40
Siemens
RCBO C40A,4P8M,300MA,AC
5SU1644-1RC63.pdf54 Pages, 2662 KB, Original
5SU1644-1RC63
Siemens
RCBO C63A,4P8M,300MA,AC
5SU1644-2RC32.pdf54 Pages, 2662 KB, Original
5SU1644-2RC32
Siemens
RCBO D32A,4P8M,300MA,AC
5SU1644-2RC40.pdf54 Pages, 2662 KB, Original
5SU1644-2RC40
Siemens
RCBO D40A,4P8M,300MA,AC
5SU1644-2RC63.pdf54 Pages, 2662 KB, Original
5SU1644-2RC63
Siemens
RCBO D63A,4P8M,300MA,AC
5SU1644-6KK82.pdf54 Pages, 2662 KB, Original
5SU1644-6WK82.pdf54 Pages, 2662 KB, Original
5SU1644-6WK82
Siemens
RCBO elm, selective
5SU1644-7KK82.pdf54 Pages, 2662 KB, Original

Product Details Search Results:

Siemens.com/5SU1642-7KC63
RCBO, 50 kA, 4P, type A, 300 mA, C-Char, In: 63 A, Un AC: 690 V Model Product brand name SENTRON Product designation RCBO Design of the product Instantaneous General technical data Number of poles 4 Number of poles / Note 4P Number of poles / with protection 4 Tripping characteristic class C circuit-breaker / Design 5SU1 Mechanical service life (switching cycles) / typical 10\u00a0000 Overvoltage category III Voltage Surge current resistance / at (8/20) \u00b5s 1\u00a0kA Supply voltage Supply voltage for te...
6071 Bytes - 11:34:05, 02 March 2025
Siemens.com/5SU1644-0KK82
RCBO, Icn: 10 kA, 4P, Type AC, 300 mA, B char., In: 125 A, Un AC: 400 V Model Product brand name SENTRON Product designation RCBO Design of the product Instantaneous General technical data Number of poles 4 Number of poles / Note 4P Number of poles / with protection 4 Tripping characteristic class B circuit-breaker / Design 5SU1 Mechanical service life (switching cycles) / typical 10\u00a0000 Overvoltage category III Degree of pollution 2 Voltage Surge current resistance / at (8/20) \u00b5s 3\u00a0kA Supply...
6864 Bytes - 11:34:05, 02 March 2025
Siemens.com/5SU1644-1KK82
RCBO, Icn: 10 kA, 4P, Type AC, 300 mA, C-Char, In: 125 A, Un AC: 400 V Model Product brand name SENTRON Product designation RCBO Design of the product Instantaneous General technical data Number of poles 4 Number of poles / Note 4P Number of poles / with protection 4 Tripping characteristic class C circuit-breaker / Design 5SU1 Mechanical service life (switching cycles) / typical 10\u00a0000 Overvoltage category III Degree of pollution 2 Voltage Surge current resistance / at (8/20) \u00b5s 3\u00a0kA Supply ...
6806 Bytes - 11:34:05, 02 March 2025
Siemens.com/5SU1644-6KK82
RCBO, 10 kA, 4P, type A, 300 mA, B char., In: 125 A, Un AC: 400 V Model Product brand name SENTRON Product designation RCBO Design of the product Instantaneous General technical data Number of poles 4 Number of poles / Note 4P Number of poles / with protection 4 Tripping characteristic class B circuit-breaker / Design 5SU1 Mechanical service life (switching cycles) / typical 10\u00a0000 Overvoltage category III Voltage Surge current resistance / at (8/20) \u00b5s 1\u00a0kA Supply voltage Supply voltage for ...
6630 Bytes - 11:34:05, 02 March 2025
Siemens.com/5SU1644-6WK82
RCBO, 10 kA, 4P, type A, selective, 300 mA, B char., In: 125 A, Un AC: 400 V Model Product brand name SENTRON Product designation RCBO Design of the product selective General technical data Number of poles 4 Number of poles / Note 4P Number of poles / with protection 4 Tripping characteristic class B circuit-breaker / Design 5SU1 Mechanical service life (switching cycles) / typical 10\u00a0000 Overvoltage category III Voltage Surge current resistance / at (8/20) \u00b5s 5\u00a0kA Supply voltage Supply volta...
6710 Bytes - 11:34:05, 02 March 2025
Siemens.com/5SU1644-7KK82
RCBO, 10 kA, 4P, type A, 300 mA, C-Char, In: 125 A, Un AC: 400 V Model Product brand name SENTRON Product designation RCBO Design of the product Instantaneous General technical data Number of poles 4 Number of poles / Note 4P Number of poles / with protection 4 Tripping characteristic class C circuit-breaker / Design 5SU1 Mechanical service life (switching cycles) / typical 10\u00a0000 Overvoltage category III Voltage Surge current resistance / at (8/20) \u00b5s 1\u00a0kA Supply voltage Supply voltage for t...
6635 Bytes - 11:34:05, 02 March 2025
Siemens.com/5SU1644-7WK82
RCBO, 10 kA, 4P, type A, selective, 300 mA, C-Char, In: 125 A, Un AC: 400 V Model Product brand name SENTRON Product designation RCBO Design of the product selective General technical data Number of poles 4 Number of poles / Note 4P Number of poles / with protection 4 Tripping characteristic class C circuit-breaker / Design 5SU1 Mechanical service life (switching cycles) / typical 10\u00a0000 Overvoltage category III Voltage Surge current resistance / at (8/20) \u00b5s 5\u00a0kA Supply voltage Supply voltag...
6652 Bytes - 11:34:05, 02 March 2025

Documentation and Support

Use our online request for specific proposed solutions or send your technical question directly to a product specialist at request:

File NameFile Size (MB)DocumentMOQSupport
5SU1646-6FP06.pdf8.201Request
5SU1646-6FP06.pdf8.201Request